5.7.3.15. timing wait-wink (E&M Voice Port Command)
To set the max. Waiting Time between Outgoing Seizure and Wink Signal, use
timing wait-wink command. To apply the default value, use no command.
timing wait-wink milliseconds
no timing wait-wink
5.7.3.15.1. Syntax
Keyword / Argument Description
milliseconds The max. waiting time for Wink-start signal.
Unit: milliseconds.
The acceptable values are “ 100~400” .
5.7.3.15.2. Default Value
550 milliseconds
5.7.3.15.3. Command Mode
Voice-port Configuration Mode
5.7.3.15.4. Example
The below configuration sets 300msec Wait-wink Duration.
voice-port 1/0
timing wait-wink 300
5.7.3.16. timing wink-duration (E&M Voice Port Command)
To set max. Wink-Signal Duration, use timing wink-duration command. To apply
the default value, use no command.
timing wink-duration milliseconds
no timing wink-duration