voice-port 1/0
no comfort-noise
5.7.3.2. connection
To specify a connection mode for a voice port, use the connection command
in voice-port configuration mode. To disable the selected connection mode,
use the no form of this command.
connection { plar } string
no connection { plar } string
5.7.3.2.1. Syntax
Keyword / Argument Description
plar
Specifies a private line automatic ringdown (PLAR)
connection. PLAR is an autodialing mechanism
that permanently associates a voice interface with
a far-end voice interface, allowing call completion
to a specific telephone number or PBX without
dialing. When the calling telephone goes off-hook,
a predefined network dial peer is automatically
matched, which sets up a call to the destination
telephone or PBX.
string
Specifies the destination telephone number. Valid
entries are any series of digits that specify the E.164
telephone number.
5.7.3.2.2. Default Value
No connection mode is specified.
5.7.3.2.3. Command Mode
Voice-port Configuration Mode
5.7.3.2.4. Usage Guideline
Use the connection command to specify a connection mode for a specific
interface. For example, use the connection plar command to specify a PLAR